Siemens AG b45f reconstruction
Example sections of a scan reconstructed with two kernels in the Siemens scanner with an emphysema overlay highlighting voxels below -950HU. The upper row shows the original sections reconstructed with ( A ) b31f and ( B ) <t>b45f</t> kernels. The lower row shows the same sections after normalization with ( C ) b31f and ( D ) b45f kernels. The ES obtained for the ( A ) b31f original scan was 9.5 %, for the ( B ) b45f original, ES was 21.2 %, whereas for the ( C ) b31f normalized, ES was 10.1 % and for the ( D ) b45f normalized, ES was 10.9 %
B45f Reconstruction, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/b45f+reconstruction/b45f/pmc04712239-73-37-23
Average 90 stars, based on 1 article reviews
b45f reconstruction - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Example sections of a scan reconstructed with two kernels in the Siemens scanner with an emphysema overlay highlighting voxels below -950HU. The upper row shows the original sections reconstructed with ( A ) b31f and ( B ) b45f kernels. The lower row shows the same sections after normalization with ( C ) b31f and ( D ) b45f kernels. The ES obtained for the ( A ) b31f original scan was 9.5 %, for the ( B ) b45f original, ES was 21.2 %, whereas for the ( C ) b31f normalized, ES was 10.1 % and for the ( D ) b45f normalized, ES was 10.9 %

Journal: European Radiology

Article Title: Normalizing computed tomography data reconstructed with different filter kernels: effect on emphysema quantification

doi: 10.1007/s00330-015-3824-y

Figure Lengend Snippet: Example sections of a scan reconstructed with two kernels in the Siemens scanner with an emphysema overlay highlighting voxels below -950HU. The upper row shows the original sections reconstructed with ( A ) b31f and ( B ) b45f kernels. The lower row shows the same sections after normalization with ( C ) b31f and ( D ) b45f kernels. The ES obtained for the ( A ) b31f original scan was 9.5 %, for the ( B ) b45f original, ES was 21.2 %, whereas for the ( C ) b31f normalized, ES was 10.1 % and for the ( D ) b45f normalized, ES was 10.9 %

Article Snippet: The second mixed cohort (n = 369) was constructed to contain scans with both standard and sharp kernels from both manufacturers: from the Siemens group, the b31f reconstruction was chosen for 92 randomly selected subjects, and the b45f reconstruction for the remaining 91 subjects.

Techniques:

Bland-Altman plots comparing ES values for (A) original b31f and original b45f, and (B) normalized b31f and normalized b45f in the Siemens group. The mean differences are shown with a solid line ; the limits of agreement are shown with dashed lines

Journal: European Radiology

Article Title: Normalizing computed tomography data reconstructed with different filter kernels: effect on emphysema quantification

doi: 10.1007/s00330-015-3824-y

Figure Lengend Snippet: Bland-Altman plots comparing ES values for (A) original b31f and original b45f, and (B) normalized b31f and normalized b45f in the Siemens group. The mean differences are shown with a solid line ; the limits of agreement are shown with dashed lines

Article Snippet: The second mixed cohort (n = 369) was constructed to contain scans with both standard and sharp kernels from both manufacturers: from the Siemens group, the b31f reconstruction was chosen for 92 randomly selected subjects, and the b45f reconstruction for the remaining 91 subjects.

Techniques:

Correlation of ES measured for the three groups (Siemens, GE and Mixed), for each cohort, before and after normalization

Journal: European Radiology

Article Title: Normalizing computed tomography data reconstructed with different filter kernels: effect on emphysema quantification

doi: 10.1007/s00330-015-3824-y

Figure Lengend Snippet: Correlation of ES measured for the three groups (Siemens, GE and Mixed), for each cohort, before and after normalization

Article Snippet: The second mixed cohort (n = 369) was constructed to contain scans with both standard and sharp kernels from both manufacturers: from the Siemens group, the b31f reconstruction was chosen for 92 randomly selected subjects, and the b45f reconstruction for the remaining 91 subjects.

Techniques: